Welcome Research Events Publications Member Access
イメージ

Journal (2012)
1.       Hagiwara Y, Saijo Y, Ando A, Onoda Y, Suda H, Chimoto E, Hatori K, Itoi E. Comparison of articular cartilage images assessed by high-frequency ultrasound microscope and scanning acoustic microscope. Int Orthop. Vol. 6, No. 1, 185-90, 2012.
2.       Tanaka Y, Saijo Y, Fujihara Y, Yamaoka H, Nishizawa S, Nagata S, Ogasawara T, Asawa Y, Takato T, Hoshi K. Evaluation of the implant type tissue-engineered cartilage by scanning acoustic microscopy. J Biosci Bioeng. 2011 Dec 2. [Epub ahead of print]
3.       Hagiwara Y, Ando A, Onoda Y, Takemura T, Minowa T, Hanagata N, Tsuchiya M, Watanabe T, Chimoto E, Suda H, Takahashi N, Sugaya H, Saijo Y, Itoi E. Coexistence of fibrotic and chondrogenic process in the capsule of idiopathic frozen shoulders. Osteoarthritis Cartilage. 2011 Dec 22. [Epub ahead of print]


Journal (2011)
1.       Nakajima H, Sugawara S, Kameyama T, Tabuchi H, Ohtsuki S, Tanaka M, Saijo Y. Location of flow axis line in the left ventricle and its interaction with local myocardial motion. J Echocardiogr, Vol. 9, No. 1, 24-27, 2011.
2.       Ando A, Suda H, Hagiwara Y, Onoda Y, Chimoto E, Saijo Y, Itoi E. Reversibility of immobilization-induced articular cartilage degeneration after remobilization in rat knee joints. Tohoku J Exp Med. Vol. 224, No. 2, 77-85, 2011.
3.       Kumagai K, Koike H, Kudo Y, Nagaoka R, Kubo K, Kobayashi K, Saijo Y. Imaging of sebaceous glands of human skin by three-dimensional ultrasound microscopy and its relation to elasticity. Conf Proc 33rd IEEE Eng Med Biol Soc. 7199-7202, 2011.
4.       Tanoue H, Hagiwara Y, Kobayashi K, Saijo Y. Ultrasonic tissue characterization of prostate biopsy tissues by ultrasound speed microscope. Conf Proc 33rd IEEE Eng Med Biol Soc. 8499-8402, 2011.

Journal (2010)
1.       Takayama S, Seki T, Watanabe M, Monma Y, Yang SY, Sugita N, Konno S, Saijo Y, Yambe T, Yaegashi N, Yoshizawa M, Nitta S. Brief effect of acupuncture on the peripheral arterial system of the upper limb and systemic hemodynamics in humans. J Altern Complement Med, Vol. 16, No. 7, 707-713, 2010.
2.       Takayama S, Seki T, Sugita N, Konno S, Arai H, Saijo Y, Yambe T, Yaegashi N, Yoshizawa M, Nitta S. Radial artery hemodynamic changes related to acupuncture. EXPLORE, Vol. 6, No. 2, 100-105, 2010.

Journal (2009)
1.       Hagiwara Y, Ando A, Chimoto E, Saijo Y, Ohmori-Matsuda K, Itoi E. Changes of articular cartilage after immobilization in a rat knee contracture model. J Orthop Res. Vol. 27, No. 2: 236-242, 2009.
2.       Funamoto K, Hayase T, Saijo Y, Yambe T. Numerical Experiment of Transient and Steady Characteristics of Ultrasonic-Measurement-Integrated Simulation in Three-Dimensional Blood Flow Analysis. Ann Biomed Eng. Vol. 37, No. 1: 34-49, 2009.
3.       Hagiwara Y, Saijo Y, Ando A, Chimoto E, Suda H, Onoda Y, Itoi E. Ultrasonic intensity microscopy for imaging of living cells. Ultrasonics Vol. 49, No. 3: 386?388, 2009.
4.       Kijima H, Minagawa H, Saijo Y, Sano H, Tomioka T, Yamamoto N, Shimada Y, Okada K, Itoi E. Degenerated coracoacromial ligament in shoulders with rotator cuff tears shows higher elastic modulus: measurement with scanning acoustic microscopy. J Orthop Sci. Vol. 14, No.1: 62-7, 2009.
5.       Saijo Y. Acoustic microscopy: latest developments and applications. Imaging in Medicine, Vol. 1, No. 1, 47-63, 2009.

Journal (2008)
1.       Santos Filho E, Saijo Y, Tanaka A, Yambe T, Yoshizawa M. Fractal dimension of 40 MHz intravascular ultrasound radio frequency signals. Ultrasonics, Vol. 48, No. 1, 35-39, 2008.
2.       Santos Filho E, Saijo Y, Tanaka A, Yoshizawa M. Detection and quantification of calcifications in intravascular ultrasound images by automatic thresholding. Ultrasound Med Biol. Vol. 34, No. 1: 160-165, 2008.
3.       Shiraishi Y, Yambe T, Saijo Y, Sato F, Tanaka A, Yoshizawa M, Sugai TK, Sakata R, Luo Y, Park Y, Uematsu M, Umezu M, Fujimoto T, Masumoto N, Liu H, Baba A, Konno S, Nitta S, Imachi K, Tabayashi K, Sasada H, Homma D. Sensorless control for a sophisticated artificial myocardial contraction by using shape memory alloy fibre. Conf Proc IEEE Eng Med Biol Soc. 2008: 711-714, 2008.
4.       Saijo Y, Kobayashi K, Okada N, Hozumi N, Hagiwara Y, Tanaka A, Iwamoto T. High frequency ultrasound imaging of surface and subsurface structures of fingerprints. Conf Proc IEEE Eng Med Biol Soc. 2008: 2173-2176, 2008.
5.       Iwamoto T, Saijo Y, Hozumi N, Kobayashi K, Okada N, Tanaka A, Yoshizawa M. High frequency ultrasound characterization of artificial skin. Conf Proc IEEE Eng Med Biol Soc. 2008: 2185-2188, 2008.
6.       Funamoto K, Hayase T, Saijo Y, Yambe T. Numerical experiment for ultrasonic-measurement-integrated simulation of three-dimensional unsteady blood flow. Ann Biomed Eng. Vol. 36, No. 8: 1383-97, 2008.
7.       Mineta M, Sano H, Ichinose R, Saijo Y, Itoi E. Elasticity of the supraspinatus tendon-muscle unit is preserved after acute tendon tearing in the rabbit. Tohoku J Exp Med. Vol. 216, No. 1: 17-24, 2008.

Journal (2007)
1.       Saijo Y, Hozumi N, Kobayashi K, OkadaN, Santos Filho ED, Sasaki H, Yambe T, Tanaka M. Ultrasonic tissue characterization of atherosclerosis by a speed-of-sound microscanning system. IEEE Trans Ultrason Ferroelectr Freq Control. Vol. 54, No. 8: 1571-1577, 2007.
2.       Hattori K, Sano H, Saijo Y, Kita A, Hatori M, Kokubun S, Itoi E. Measurement of soft tissue elasticity in the congenital clubfoot using scanning acoustic microscope. J Pediatr Orthop B. Vol. 16, No. 5: 357-362, 2007.
3.       Tanaka A, Saijo Y. Blood flow visualization of left atrial spontaneous echo contrast (SEC) using gradient based optical flow estimation. Conf Proc IEEE Eng Med Biol Soc. Vol. 1: 4500-3, 2007.
4.       Shiraishi Y, Yambe T, Saijo Y, Sato F, Tanaka A, Yoshizawa M, Ogawa D, Wada Y, Itoh S, Sakata R, Park Y, Uematsu M, Umezu M, Fujimoto T, Masumoto N, Liu H, Baba A, Konno S, Nitta S, Imachi K, Tabayashi K, Sasada H, Homma D. Morphological approach for the functional improvement of an artificial myocardial assist device using shape memory alloy fibres. Conf Proc IEEE Eng Med Biol Soc. Vol. 1: 3974-7, 2007.
5.       Saijo Y, Hozumi N, Kobayashi K, Okada N, Ishiguro T, Hagiwara Y, Dos Santos Filho E, Yambe T. Ultrasound speed and impedance microscopy for in vivo imaging. Conf Proc IEEE Eng Med Biol Soc. Vol. 1: 1350-3, 2007.
6.       Liu H, Luo Y, Higa M, Zhang X, Saijo Y, Shiraishi Y, Sekine K, Yambe T. Biochemical evaluation of an artificial anal sphincter made from shape memory alloys. J Artif Organs. Vol. 10: 223-227, 2007.
7.       Okazaki T, Ebihara S, Asada M, Yamanda S, Saijo Y, Shiraishi Y, Ebihara T, Niu K, Mei H, Arai H, Yambe T. Macrophage colony-stimulating factor improves cardiac function after ischemic injury by inducing vascular endothelial growth factor production and survival of cardiomyocytes. Am J Pathol. Vol. 171, No. 4: 1093-1103, 2007.

Journal (2006)
1.       van der Steen AFW, Baldewsing RA, Degertekin FL, Emelianov S, Frijlink ME, Furukawa Y, Goertz D, Karaman M, Khuri-Yakub PT, Kim K, Mastik F, Moriya T, Oralkan O, Saijo Y, Schaar JA, Serruys PW, Sethuraman S, Tanaka A, Vos HJ, Witte R, O’Donnell M. IVUS beyond the horizon. Eurointerv, Vol. 2: 132-142, 2006.
2.       Sano H, Hattori K, Saijo Y, Kokubun S. Does decalcification alter the tissue sound speed of rabbit supraspinatus tendon insertion? In vitro measurement using scanning acoustic microscopy. Ultrasonics, Vol. 44, No. 3: 297-301, 2006.
3.       Saijo Y, Hozumi N, Lee C, Nagao M, Kobayashi K, Oakada N, Tanaka N, Santos Filho ED, Sasaki H, Tanaka M, Yambe T. Ultrasonic speed microscopy for imaging of coronary artery. Ultrasonics, Vol. 44; Suppl. 1: e51-55, 2006.
4.       Saijo Y, Tanaka A, Iwamoto T, Dos Santos Filho E, Yoshizawa M, Hirosaka A, Kijima M, Akino Y, Hanadate Y, Yambe T. Intravascular two-dimensional tissue strain imaging. Ultrasonics, Vol. 44; Suppl. 1: e147-151, 2006.
5.       Liu H, Saijo Y, Zhang X, Shiraishi Y, Luo Y, Maruyama M, Higa M, Sekine K, Yambe T. Impact of type A behavior on brachial-ankle pulse wave velocity in Japanese. Tohoku J Exp Med, Vol. 209, No. 1: 15-21, 2006.
6.       Sano H, Saijo Y, Kokubun S. Non-mineralized fibrocartilage shows the lowest elastic modulus in the rabbit supraspinatus tendon insertion: measurement with scanning acoustic microscopy. J Shoulder Elbow Surg, Vol. 15, No. 6: 743-749, 2006.
7.       Hagiwara Y, Saijo Y, Chimoto E, Akita H, Sasano Y, Matsumoto F, Kokubun S. Increased elasticity of capsule after immobilization in a rat knee experimental model assessed by scanning acoustic microscopy. Upsala J Med Sci. Vol. 111, No. 3: 303-313, 2006.

Journal (2005)
1.       Funamoto K, Hayase T, Saijo Y, Yambe T. Detection and correction of aliasing in ultrasonic measurement of blood flows with Ultrasonic-Measurement-Integrated simulation. Technol Health Care. Vol 13, No.4: 331-44, 2005.
2.       Saijo Y, Sasaki H, Hozumi N, Kobayashi K, Tanaka M, Yambe T. Sound speed scanning acoustic microscopy for biomedical applications. Technol Health Care. Vol. 13, No. 4: 261-7, 2005.
3.       Funamoto K, Hayase T, Shirai A, Saijo Y, Yambe T. Fundamental study of ultrasonic-measurement-integrated simulation of real blood flow in the aorta. Ann Biomed Eng. Vol. 33, No. 4: 415-28, 2005.
4.       Watanabe S, Suzuki N, Kudo A, Suzuki T, Abe S, Suzuki M, Komatsu S, Saijo Y, Murayama N. Influence of aging on cardiac function examined by echocardiography. Tohoku J Exp Med. Vol. 207, No.1: 13-9, 2005.
5.       Watanabe M, Sekine K, Hori Y, Shiraishi Y, Maeda T, Honma D, Miyata G, Saijo Y, Yambe T. Artificial esophagus with peristaltic movement. ASAIO J. Vol. 51, No.2: 158-61, 2005.
6.       Santos Filho E, Yoshizawa M, Tanaka A, Saijo Y, Iwamoto T. Moment based texture segmentation of intravascular ultrasound images. J Med Ultrasonics. Vol. 32, No. 3: 91-99, 2005.
7.       Shiraishi Y, Yambe T, Sekine K, Saijo Y, Wang Q, Liu H, Nitta S, Konno S, Masumoto N, Nagatoshi J, Itoh S, Park Y, Uematsu M, Umezu M, Ogawa D, Olegario P, Sato F, Yoshizawa M, Tanaka A, Tabayashi K, Sasada H, Fujimoto T, Homma D, Higa M, Hori Y. Development of an artificial myocardium using a covalent ahape-memory alloy fiber and its cardiovascular diagnostic response. Conf Proc IEEE Eng Med Biol Soc. Vol. 1, No. 1: 406-408, 2005.
8.       Uematsu M, Shiraishi Y, Sekine K, Yambe T, Saijo Y, Park Y, Ando H, Matsumoto T, Takeda S, Iwasaki K, Umezu M. An innovative approach to evaluate a cardiac function based on surface measurement. Conf Proc IEEE Eng Med Biol Soc. Vol. 7: 7640-3, 2005.
9.       Dos Santos E, Yoshizawa M, Tanaka A, Saijo Y, Iwamoto T. Detection of luminal contour using fuzzy clustering and mathematical morphology in intravascular ultrasound images. Conf Proc IEEE Eng Med Biol Soc. Vol. 4: 3471-4, 2005.

Journal (2004)
1.       Saijo Y, Miyakawa T, Sasaki H, Tanaka M, Nitta S. Acoustic properties of aortic aneurysm obtained with scanning acoustic microscopy.  Ultrasonics, Vol. 42, No. 1-9: 695-698, 2004.
2.       Saijo Y, Nitta S, Kobayashi K, Arai H, Nemoto Y. Development of an ultra-portable echo device connected to USB port. Ultrasonics, Vol. 42, No. 1-9: 699-703, 2004.
3.       Hozumi N, Yamashita R, Lee CK, Nagao M, Kobayashi K, Saijo Y, Tanaka M, Tanaka N, Ohtsuki S. Time?frequency analysis for pulse driven ultrasonic microscopy for biological tissue characterization. Ultrasonics, Vol. 42, No. 1-9: 717-722, 2004.
4.       Saijo Y, Tanaka A, Owada N, Akino Y, Nitta S. Tissue velocity imaging of coronary artery by rotating-type intravascular ultrasound. Ultrasonics, Vol. 42, No. 1-9: 753-757, 2004.
5.       Sano H, Saijo Y, Kokubun S. Material properties of the supraspinatus tendon at its insertion ? A measurement with the scanning acoustic microscopy. J Musculoskeletal Res Vol. 8, No. 1: 29-34, 2004.
6.       Suzuki S, Hao B, Matsuda Y, Tabata T, Hoshikawa Y, Saijo Y, Kondo T. Paclitaxel prevents loss of pulmonary endothelial barrier integrity during cold preservation. Transplantation Vol. 78, No. 4: 524-529, 2004.
7.       Yambe T, Sekine K, Shiraishi Y, Watanabe M, Shibata M, Yamaguchi T, Quintian W, Duan X, Jian LH, Yoshizawa M, Tanaka A, Matsuki H, Sato F, Haga Y, Esashi M, Tabayashi K, Mitamura Y, Sasada H, Sato E, Saijo Y, Nitta S. Addition of rhythm to non-pulsatile circulation. Biomed Pharmacother. Vol. 58, Suppl 1: S145-9, 2004.
8.       Yambe T, Yoshizawa M, Saijo Y, Yamaguchi T, Shibata M, Konno S, Nitta S, Kuwayama T. Brachio-ankle pulse wave velocity and cardio-ankle vascular index (CAVI). Biomed Pharmacother. Vol. 58, Suppl 1: S95-8, 2004.
9.       Yambe T, Kovalev YA, Milyagina IA, Milyagin VA, Shiraishi Y, Yoshizawa M, Saijo Y, Yamaguchi T, Shibata M, Nitta S. A Japanese-Russian collaborative study on aging and atherosclerosis. Biomed Pharmacother. Vol. 58, Suppl 1: S91-4, 2004.

Journal (2003)
1.       Sasaki H, Saijo Y, Tanaka M, Nitta S. Influence of tissue preparation on the acoustic properties of tissue sections at high frequencies. Ultrasound Med Biol, Vol. 29, No. 9: 1367-72, 2003.
2.       Yambe T, Shiraishi Y, Yoshizawa M, Tanaka A, Abe K, Sato F, Matsuki H, Esashi M, Haga Y, Maruyama S, Takagi T, Luo Y, Okamoto E, Kubo Y, Osaka M, Nanka S, Saijo Y, Mibiki Y, Yamaguchi T, Shibata M, Nitta S. Artificial myocardium with an artificial baroreflex system using nano technology. Biomed Pharmacother Vol. 57, Suppl 1: 122s-125s, 2003.
3.       Yambe T, Yoshizawa M, Tanaka A, Abe K, Kawano S, Matsuki H, Maruyama S, Amae S, Wada N, Kamiyama T, Takagi T, Luo R, Hayashi J, Kovalev YA, X D Sha D, Nanka S, Saijo Y, Mibiki Y, Shibata M, Nitta S. Recent progress in artificial organ research at Tohoku University. Artif Organs Vol. 27, No.1: 2-7, 2003.
4.       Hozumi N, Yamashita R, Lee CK, Nagao M, Kobayashi K, Saijo Y, Tanaka M, Tanaka N, Ohtsuki S. Ultrasonic sound speed microscope for biological tissue characterization driven by nanosecond pulse. Acoust Sci Tech. Vol. 24, No. 6, 386-390, 2003.

Journal (2002)
1.       Saijo Y, Jorgensen CS, Mondek P, Sefranek V, Paaske W. Acoustic inhomogeneity of carotid arterial plaques determined by GHz frequency range acoustic microscopy. Ultrasound Med Biol, Vol. 28, No. 7: 933-937, 2002.
2.       Saijo Y, Akimoto H, Saiki Y, Tabayashi K, Horinouchi T, Kobayashi T, Nitta S. Proximal (entry) tear of dissecting aortic aneurysm visualized by three-dimensional echocardiography. J Thorac Cardiovasc Surg Vol. 124, No. 6: 1245-1246, 2002.

Journal (1991-2001)
1.       Saijo Y, Jorgensen CS, Falk E. Ultrasonic tissue characterization of collagen in lipid-rich plaques in apoE-deficient mice. Atherosclerosis Vol. 158, No. 2: 289-295, 2001.
2.       Saijo Y, Ohashi T, Sasaki H, Sato M, Jorgensen CS, Nitta S. Application of scanning acoustic microscopy for assessing stress distribution in atherosclerotic plaque. Ann Biomed Eng, Vol. 29, No. 12: 1048-53, 2001.
3.       Saijo Y, Sasaki H, Sato M, Nitta S, Tanaka M. Visualization of human umbilical vein endothelial cells by acoustic microscopy. Ultrasonics Vol. 38, No. 1-8: 396-399, 2000.
4.       Saijo Y, Okawai H, Sasaki H, Yambe T, Nitta S, Tanaka M, Kobayashi K, Honda Y. Evaluation of the inner-surface morphology of an artificial heart by acoustic microscopy. Artif Organs. 2000 Vol. 24, No. 1: 64-69, 2000.
5.       Saijo Y, Chubachi N. Microscopy. Ultrasound Med Biol. Vol. 26, Suppl. 1: S30-32, 2000.
6.       Saijo Y, Izutsu K, Sonobe T, Okuyama Y, Yambe T, Nitta S. Successful closure of coronary-bronchial artery fistula with vein graft-coated stent. Catheter Cardiovasc Interv. Vol. 46, No. 2: 214-217, 1999.
7.   Saijo Y, Jorgensen C, Falk E, Nitta S. Collagen characterization of fibrous caps in Apo-E deficient mice by acoustic microscopy. Circulation Vol. 100, No. 18: I-251, 1999.
8.       Saijo Y, Sasaki H, Okawai H, Nitta S, Tanaka M. Acoustic properties of atherosclerosis of human aorta obtained with high-frequency ultrasound. Ultrasound Med Biol. Vol. 24, No. 7: 1061-1064, 1998.
9.       Saijo Y, Tanaka M, Okawai H, Sasaki H, Nitta S, Dunn F. Ultrasonic tissue characterization of infarcted myocardium by scanning acoustic microscopy. Ultrasound Med Biol Vol. 23, No. 1: 77-85, 1997.
10.       Sasaki H, Saijo Y, Tanaka M, Nitta S, Terasawa Y, Yambe T, Taguma Y. Acoustic properties of dialysed kidney by scanning acoustic microscopy. Nephrol Dial Transplant. Vol. 12, No. 10: 2151-2154, 1997.
11.       Sasaki H, Saijo Y, Tanaka M, Nitta S, Yambe T, Terasawa Y. Characterization of renal angiomyolipoma by scanning acoustic microscopy. J Pathol. Vol. 181, No. 4: 455-461, 1997.
12.       Sasaki H, Saijo Y, Tanaka M, Okawai H, Terasawa Y, Yambe T, Nitta S. Influence of tissue preparation on the high-frequency acoustic properties of normal kidney tissue. Ultrasound Med Biol Vol. 22, No. 9: 1261-1265, 1996.
13.       Sasaki H, Tanaka M, Saijo Y, Okawai H, Terasawa Y, Nitta S, Suzuki K. Ultrasonic tissue characterization of renal cell carcinoma tissue. Nephron Vol. 74, No. 1: 125-130, 1996.
14.       Saijo Y, Tanaka M, Yamamoto A, Endo N, Takahashi K, Satoh N, Chiba S. Estimation of intracardiac local flow state by two-dimensional display of the stream lines. J Cardiol. Vol. 23, Suppl. XXXVII: 125-131, 1993.
15.       Saijo Y, Tanaka M, Okawai H, Dunn F. The ultrasonic properties of gastric cancer tissues obtained with a scanning acoustic microscope system. Ultrasound Med Biol Vol. 17, No. 7: 709-714, 1991.

Copyright(C) 2011 Saijo Lab All Rights Reserved